Simulation Of Acidic Water Purification Process In Refinery Based On Determining Appropriate Operating Conditions

Mufida Bey (1)
(1) Industrial Engineering Department, Faculty of Engineering, Sabratha Uuniversity, Reqdalin, Libya

Abstract

Acidic process water produced by refineries contains some hazardous pollutants such as (H2S and NH3). Acid water extraction units remove both compounds from the water. The removed contaminants are sent to a sulphur recovery unit to produce sulphur and avoid any acid emissions contrary to environmental regulations. Water pollution is a problem that concerns all people in the world. In view of the importance of preserving the environment and water resources, in this research, the simulation of the acid water treatment unit in the refinery was studied using the Aspen Hysys software based on determining the appropriate operating conditions. The NRTL electrolyte activity coefficient model was used to predict the system's thermodynamic behaviour. The simulation results showed that the suitable temperature for the feed entering the tower is about 38°C and the convenient distance for the trays in the disposal tower is 0.54 mm. Under these conditions, the concentration of hydrogen sulphide 0.1694 and 0.2418 of ammonia in the acid gas exiting the tower reaches its maximum at a molar flow rate of the mixture of about 39.86 kgmol/h, according to the economic considerations of the operating tower.

Full text article

Generated from XML file

References

[1]-Patel H, Madam war D. Effects of temperatures and organic loading rates on bio methanation of acidic petrochemical wastewater using an anaerobic up flow fixed-film reactor. BioresourTechnol 2002; 82:65–71.

[2]-Rasheed, Q.J., Pandian, K. and Muthukumar, K. (2011) ‘Treatment of petroleum refinery wastewater by ultrasound-dispersed nanoscale zero-valent iron particles’, Ultrasonics Sonochemistry, 18(5), pp. 1138–1142. doi: 10.1016/j.ultsonch.2011.03.015.

[3]-Karkare, M.V. and Murthy, Z. (2010) ‘Kinetic study and modeling of aerobic biological oxidation of organic wastewater’, Chemical Product and Process Modeling, 5(1). doi:10.2202/1934-2659.1467.

[4]-Mathur, A.K. and Majumder, C.B. (2008) ‘Biofiltration and kinetic aspects of a bio trickling filter for the removal of paint solvent mixture laden air stream’, Journal of Hazardous Materials, 152(3), pp. 1027–1036. doi: 10.1016/j.jhazmat.2007.07.112.

[5]-Chao, Y.-M., Tseng, I.-C. and Chang, J.-S. (2006) ‘Mechanism for sludge acidification in aerobic treatment of coking wastewater’, Journal of Hazardous Materials, 137(3), pp. 1781–1787. doi: 10.1016/j.jhazmat.2006.05.024.

[6]-Alva-Argaez, A., Kokases, A.C. and Smith, R. (2007) ‘The design of water-using systems in petroleum refining using a water-pinch decomposition’, Chemical Engineering Journal, 128(1), pp. 33–46. doi: 10.1016/j.cej.2006.10.001.

[7]-Yavuz, Y., Okpara, A.S. and govern, Ü.B. (2010) ‘Treatment of petroleum refinery wastewater by electrochemical methods’, Desalination, 258(1–3), pp. 201–205. doi: 10.1016/j.desal.2010.03.013.

[8]-Yan, L. et al. (2011) ‘Electrochemical treatment of petroleum refinery wastewater with three-dimensional multi-phase electrode’, Desalination, 276(1–3), pp. 397–402. doi: 10.1016/j.desal.2011.03.083.

[9]-Hasan, D.B., Abdul Aziz, A.R. and Daud, W.M. (2012) ‘Oxidative mineralization of petroleum refinery effluent using Fenton-like process’, Chemical Engineering Research and Design, 90(2), pp. 298–307. doi: 10.1016/j.cherd.2011.06.010.

[10]-Davar Nejad, R. et al. (2015) ‘Numerical Analysis of petroleum refinery wastewater treatment using electro-Fenton process’, Chemical Product and Process Modeling, 10(1), pp. 11–16. doi:10.1515/cppm-2014-0020.

[11]-Lee, D. et al. (2002) ‘Dynamic simulation of the sour water stripping process and modified structure for effective pressure control’, Chemical Engineering Research and Design, 80(2), pp. 167–177. doi:10.1205/026387602753501889.

[12]-Hassan, S.Q. and Timberlake, D.L. (1992) ‘Steam stripping and batch distillation for the removal and/or recovery of volatile organic compounds from industrial wastes’, Journal of the Air & Waste Management Association, 42(7), pp. 936–943. doi:10.1080/10473289.1992.10467044.

[13]-Hwang, Y.L., Keller, G.E. and Olson, J.D. (1992) ‘Steam stripping for removal of organic pollutants from water. 1. stripping effectiveness and stripper design’, Industrial & Engineering Chemistry Research, 31(7), pp. 1753–1759. doi:10.1021/ie00007a021.

[14]-Darton, R.C., Van Grinsven, P.F.A. and Simon, M.M. (1978) Development in steam stripping of Sour water, Chem. Eng. (London); (United Kingdom). Available at: https://www.osti.gov/etdeweb/biblio/6826036 (Accessed: 25 June 2023).

[15]-Melin, G.A., Niedzwiecki, J.L. and Goldstein, A.M. (1975) Optimum design of sour water strippers. [injection of base into lower section for NH/sub-3/ and H/Sub 2/s removal], Chem. Eng. Prog.; (United States). Available at: https://www.osti.gov/biblio/5104209 (Accessed: 25 June 2023).

[16]-Kohl, A.L. and Nielsen, R.B. (1997) Gas purification. Houston: Gulf Pub.

[17]-Higman, C. and Van der Burgt, M. (2003) Gasification. Gulf Professional Publishing. Elsevier, New York.

[18]-Lee, D. et al. (2002) ‘Dynamic simulation of the sour water stripping process and modified structure for effective pressure control’, Chemical Engineering Research and Design, 80(2), pp. 167–177. doi:10.1205/026387602753501889.

[19]-Yu, Z. et al. (2010) ‘Process development, simulation, and industrial implementation of a new coal-gasification wastewater treatment installation for phenol and ammonia removal’, Industrial & Engineering Chemistry Research, 49(6), pp. 2874–2881. doi:10.1021/ie901958j.

[20]-Lin, S. H., & Wang, C. S. (2002). Treatment of high-strength phenolic wastewater by a new two-step method. Journal of Hazardous Materials,90(2), 205-216.

[21]-Karbhari, B. K., & Taniela, A. (2003). Continuous electrochemical treatment of phenolic wastewater in a tubular reactor. Water Research,37(7), 1505-1514.

[22]-Venkateswaran, P., & Plaintively, K. (2006). Recovery of phenol from aqueous solution by supported liquid membrane using vegetable oils as liquid membrane. Journal of Hazardous materials,131(1-3), 146-152.

[23]-Aspen Technology. Aspen plus Electrolytes Manual; Aspen Technology Inc.: Cambridge, MA, 1998.

Authors

Mufida Bey
[email protected] (Primary Contact)
Bey, M. (2023). Simulation Of Acidic Water Purification Process In Refinery Based On Determining Appropriate Operating Conditions. Journal of Pure & Applied Sciences , 22(3), 271-274. https://doi.org/10.51984/jopas.v22i3.2825

Article Details

How to Cite

Bey, M. (2023). Simulation Of Acidic Water Purification Process In Refinery Based On Determining Appropriate Operating Conditions. Journal of Pure & Applied Sciences , 22(3), 271-274. https://doi.org/10.51984/jopas.v22i3.2825

Similar Articles

You may also start an advanced similarity search for this article.

Assessment of Groundwater Wells Pollution by Some Heavy Metals in El-Beida City-Libya

Galal M. Elmanfe, Tariq A. Tyeb, Kareima A.Abdelghani, Adel A. Abdulathim, Jibreel A. Asbeeh,...
Abstract View : 1660
Download :589

A Comparison of Some Methods for Estimating the Weibull Distribution Parameters

Alsaidi Altaher, Abdslam Suliman, Nuri Ali, Jamela Abo-Neran, Iman Abo-Grarah
Abstract View : 950
Download :318